1.
Odovtos (En línea) ; 24(2)ago. 2022.
Article in English | LILACS, SaludCR | ID: biblio-1386601

ABSTRACT

Abstract The aim of this study was to evaluate the effect of using a higher rotation speed with the XP-endo Shaper (XPS) on apically extruded debris and operation time during endodontic treatment and retreatment procedures. Sixty mesial roots of mandibular first molar teeth were randomly assigned to four groups (Initial treatment groups: XPS used at 1000 or 3000rpm rotation speeds and Retreatment groups: XPS used at 1000 or 3000rpm rotation speeds). During the initial treatment and retreatment procedures preweighed eppendorf tubes were used to collect apically extruded debris, and the operation time was recorded in seconds. The extruded debris was quantified by subtracting the preinstrumentation from the postinstrumentation weight of the Eppendorf tubes. Data were analysed using two-way ANOVA at a significance level of 0.05. In all groups, the use of the XPS at 1000 or 3000rpm rotation speeds had no statistically significant effect on the amount of apically extruded debris (p>0.05). The use of the XPS at a 3000rpm rotation speed significantly decreased the instrumentation time (p<0.05). In summary, the use of the XPS at high rotation speeds in initial treatment and retreatment procedures did not have a significant effect on the amount of apically extruded debris but significantly decreased the operation time.


Resumen El objetivo de este estudio fue evaluar el efecto del uso de una mayor velocidad de rotación con XP-endo Shaper (XPS) sobre los desechos extruidos apicalmente y el tiempo de operación durante el tratamiento endodóntico y los procedimientos de retratamiento. Sesenta raíces mesiales de los primeros molares mandibulares se asignaron aleatoriamente a cuatro grupos (grupos de tratamiento inicial: XPS usado a velocidades de rotación de 1000 o 3000rpm y grupos de retratamiento: XPS usado a velocidades de rotación de 1000 o 3000rpm). Durante el tratamiento inicial y los procedimientos de retratamiento se utilizaron tubos Eppendorf pesados previamente para recoger los desechos extruidos apicalmente, y el tiempo de operación se registró en segundos. Los residuos extruidos se cuantificaron restando la preinstrumentación del peso postinstrumentación de los tubos Eppendorf. Los datos se analizaron mediante ANOVA bidireccional a un nivel de significación de 0,05. En todos los grupos, el uso del XPS a velocidades de rotación de 1000 o 3000rpm no tuvo un efecto estadísticamente significativo sobre la cantidad de detritos extruidos apicalmente (p>0.05). El uso del XPS a una velocidad de rotación de 3000rpm disminuyó significativamente el tiempo de instrumentación (p<0.05). En resumen, el uso del XPS a altas velocidades de rotación en los procedimientos de tratamiento inicial y retratamiento no tuvo un efecto significativo en la cantidad de detritos extruidos apicalmente, pero disminuyó significativamente el tiempo de operación.


Subject(s)
Humans , Dental Waste , Dentistry, Operative , Endodontics
2.
Article | IMSEAR | ID: sea-216809

ABSTRACT

Aim: This study aimed to systematically review available literature of in vitro studies on apical extrusion of debris through rotary instrumentation in comparison to manual instrumentation in pediatric endodontics, and also to perform a comparison between various rotary instrumentation systems for assessment of debris extrusion. Materials and Methods: A comprehensive search was conducted on PubMed, Medline, Cochrane Library, Embase, Scopus, and Google Scholar without any language restriction and year of publication. A planned search strategy was made for PubMed and applied to other databases. After full-text reading, 7 articles were selected for quantitative synthesis. Modified CONSORT checklist of items for reporting in vitro studies of dental materials was used for quality assessment of included studies. Results: Root canal preparation with rotary instrumentation led to lesser apical debris extrusion than manual instrumentation. Self-adjusting file system was associated with the least debris extrusion among all included studies, followed by ProTaper Next, Kedo-S, ProTaper, K3, Mtwo, Revo-S, and Wave One. Conclusion: More apical debris extrusion was seen with manual instrumentation than rotary instrumentation. Furtrhermore, variance in debris extrusion was seen with different rotary file systems.

3.
J. oral res. (Impresa) ; 8(4): 325-330, nov. 5, 2019. graf
Article in English | LILACS | ID: biblio-1145355

ABSTRACT

The aim of the study was to quantify and compare apical debris extrusion in two systems of continuous and reciprocating rotary instrumentation with, and without, the use of a patency file. An experimental study was carried out in 120 mesial roots of lower first molars, which were randomized in the following 4 groups: Group A. Reciproc (VDW) R25 without a patency file, Group B Mtwo (VDW) without a patency file, Group C Reciproc (VDW) R25 with a patency file and Group D Mtwo with a patency file. Groups A, B and C presented statistically significant differences in comparison to group D, Mtwo with the use of a patency file (p<0.008 to 95% reliability). In conclusion, the greater amount of debris extruded through the apex occurred in roots instrumented with the reciprocating rotary system; this difference was statistically significant in relation to teeth treated with the Mtwo continuous rotary system with the use of a patency file.


El objetivo del estudio fue cuantificar y comparar la extrusión de residuos apicales en dos sistemas de instrumentación endodónticos rotativos, continuo y recíproco, con y sin el uso de una lima de pasaje apical. Se realizó un estudio experimental en 120 raíces mesiales de primeros molares inferiores, que se aleatorizaron en los siguientes 4 grupos: Grupo A. Reciproc (VDW) R25 sin lima de pasaje apical, Grupo B Mtwo (VDW) sin lima de pasaje apical, Grupo C Reciproc (VDW) R25 con lima de pasaje apical y Grupo D Mtwo con lima de pasaje apical. Los grupos A, B y C presentaron diferencias estadísticamente significativas encomparación con el grupo D, Mtwo con el uso de una lima de pasaje apical (p<0.008 a 95% de confiabilidad). En conclusión, la mayor cantidad de residuos extruidos a través del ápice ocurrió en raíces preparadas con el sistema rotativo recíproco; Esta diferencia fue estadísticamente significativa en relación a los dientes tratados con el sistema rotativo continuo Mtwo con el uso de una lima de pasaje apical.


Subject(s)
Humans , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Tooth Apex , Dental Instruments , Dental Pulp Cavity
4.
Braz. dent. j ; 30(4): 363-367, July-Aug. 2019. tab
Article in English | LILACS | ID: biblio-1011565

ABSTRACT

Abstract The present study evaluated the amount of apically extruded debris after chemo-mechanical preparation (CMP) associated with passive ultrasonic irrigation (PUI) using four different root canal irrigants, namely, 6% sodium hypochlorite (NaOCl), 2% chlorhexidine gel + saline solution (2% CHXg+SS), 2% chlorhexidine solution (2% CHXs) and SS alone. Sixty mandibular premolars with single straight root canals were selected and randomly assigned into 4 groups (n=15) according to the root canal irrigant used as follows: G1 (PUI + NaOCl), G2 (PUI + CHXg+SS), G3 (PUI+CHXs) and G4 (PUI+SS). Reciproc® R25 files (25/.08) were used during CMP and the debris extruded from each tooth were collected in pre-weighted Eppendorf tubes and dried. The average weight of debris was assessed by using an analytical microbalance. Data were statistically analysed by using ANOVA and post-hoc Tukey's test (a=0.05). Debris extrusion was observed in all groups, irrespective of the root canal irrigating, with 2% CHXg + SS being associated with lower debris extrusion compared to other irrigants (p<0.05). No significant differences were observed between 6% NaOCl, 2% CHXs and SS. In conclusion, passive ultrasonic irrigation did not completely prevent apically extrusion of debris. PUI performed with 2% chlorhexidine gel + saline solution significantly minimized debris extrusion compared to 6% sodium hypochlorite, chlorhexidine solution and saline solution.


Resumo O presente estudo avaliou a quantidade de debris extruídos apicalmente após o preparo químico-mecânico (PQM) associado à irrigação ultrassônica passiva (IUP) em associação com quatro diferentes irrigantes - hipoclorito de sódio 6% (NaOCl), clorexidina gel 2% + solução salina (CLXg 2% + SS), solução de clorexidina 2% (CLXs 2%) e SS. Sessenta pré-molares inferiores com canais radiculares únicos e retos foram selecionados e aleatoriamente distribuídos em 4 grupos (n=15) de acordo com o irrigante utilizado: G1 (IUP + NaOCl), G2 (IUP + CLXg + SS), G3 (IUP + CLXs) e G4 (IUP + SS). Limas Reciproc® R25 (25/.08) foram utilizadas durante o PQM e os debris extruídos de cada dente foram coletados em tubos Eppendorf pré-pesados e secos. O peso médio de debris foi avaliado através de microbalança analítica, e os dados foram analisados estatisticamente utilizando ANOVA e teste de Tukey post hoc (a=0.05). Extrusão de debris foi observada em todos os grupos, independente do irrigante. CHXg 2% + SS foram associados a menor extrusão de debris comparado aos demais irrigantes (p<0.05). Não foram observadas diferenças estatisticamente significativas entre NaOCl 6%, CLXs 2% e SS. Concluindo, irrigação ultrassônica passiva não preveniu completamente a extrusão apical de debris, entretanto, IUP realizada com CLXg 2% + SS minimiza significativamente a extrusão de debris comparado ao NaOCl 6%, CLXs 2% e SS.


Subject(s)
Humans , Root Canal Irrigants , Root Canal Preparation , Ultrasonics , Tooth Apex , Dental Pulp Cavity , Therapeutic Irrigation
5.
Braz. dent. j ; 29(2): 184-188, Mar.-Apr. 2018. graf
Article in English | LILACS | ID: biblio-951535

ABSTRACT

Abstract This study evaluated the amount of apically extruded debris after chemo-mechanical preparation (CMP) using positive and negative pressure irrigation systems [Conventional irrigation (CI) and EndoVac (EV)] in association with different irrigants [6% Sodium Hypochlorite (NaOCl), 2% Chlorhexidine gel + saline solution (CHXg + SS), 2% Chlorhexidine solution (CHXs) or Saline solution (SS)]. Eighty mandibular premolars with single root canals were selected and randomly assigned into 8 groups (n = 10) according to the irrigation system and the irrigant used during CMP: G1 (EV + NaOCl), G2 (EV + CHXg + SS), G3 (EV + CHXs), G4 (EV + SS), G5 (CI + NaOCl), G6 (CI + CHXg + SS), G7 (CI + CHXs) and G8 (CI + SS). Reciproc® R25 files (25/.08) were used during the CMP and the extruded debris from each tooth was collected in pre-weighted Eppendorf tubes and dried. The average weight of debris was assessed using a microbalance, and the data were statistically analyzed using ANOVA and the post hoc Tukey's test (a = 0.05). All groups were associated with debris extrusion. EV was the irrigation system with less extruded debris (p < 0.05). No differences were observed regarding the irrigant when EV was used. When CI was used, CHXg + SS were associated with lower debris extrusion (p < 0.05). It was concluded that no irrigation protocol succeeded in preventing debris extrusion. EV resulted in lower levels of debris extrusion than CI. The use of CHXg + SS resulted in lower debris extrusion.


Resumo Este estudo avaliou a quantidade de debris extruídos apicalmente após o preparo químico-mecânico (PQM) utilizando sistemas de irrigação com pressão positiva e negativa [irrigação convencional (IC) e EndoVac (EV)] em associação com diferentes irrigantes [hipoclorito de sódio 6% (NaOCl), clorexidina gel + solução salina (CLXg + SS), solução de clorexidina 2% (CLXs) ou solução salina (SS)]. Oitenta pré-molares inferiores com único canal radicular foram selecionados e aleatoriamente alocados em 8 grupos (n=10) de acordo com o sistema de irrigação e irrigante utilizado durante o PQM: G1 (EV + NaOCl), G2 (EV + CLXg + SS), G3 (EV + CLXs), G4 (EV + SS), G5 (IC + NaOCl), G6 (IC + CLXg + SS), G7 (IC + CLXs) e G8 (IC + SS). Limas Reciproc® R25 foram utilizadas durante o PQM e os debris extruídos de cada dente foi coletado em tubos pré-pesados e secos. O peso médio de debris foi avaliado por meio de microbalança, e os dados foram analisados estatisticamente utilizando ANOVA e teste de Tukey (a = 0.05). Todos os grupos foram associados com extrusão de debris. EV foi o sistema de irrigação com menos debris extruídos (p<0.05). Não foram observadas diferenças entre os irrigantes quando o EV foi utilizado. Quando foi utilizada IC, CLXg + SS foram associados a menor extrusão de debris (p<0.05). Concluiu-se que nenhum protocolo de irrigação conseguiu prevenir extrusão de debris. EV resultou em menores níveis de extrusão de debris que a IC. A utilização da CLXg + SS resultou em menor extrusão de debris.


Subject(s)
Humans , Root Canal Irrigants/administration & dosage , Sodium Hypochlorite/administration & dosage , Chlorhexidine/administration & dosage , Root Canal Preparation/methods , Saline Solution/administration & dosage , Therapeutic Irrigation/methods , In Vitro Techniques , Random Allocation , Tooth Apex/metabolism
6.
Restorative Dentistry & Endodontics ; : 316-323, 2017.
Article in English | WPRIM | ID: wpr-16976

ABSTRACT

OBJECTIVES: This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. MATERIALS AND METHODS: Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). RESULTS: The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. CONCLUSIONS: All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.


Subject(s)
Agar , Bacteria , Brain , Enterococcus faecalis , Ethylene Oxide , Glass , Heart , In Vitro Techniques , Molar , Stem Cells , Tooth
SELECTION OF CITATIONS